Finned tube air heat exchangers

With an Alfa Laval finned tube air heat exchanger you get a robust cooler that will deliver high performance for many years to come. Our product range covers most applications in oil & gas, data centers, hydrogen, RNG and CCUS. We supply both standardized and fully customized, engineered-to-order solutions. Thanks to their flexible designs, we can configure our heat exchangers to match your specific operating conditions, ensuring reliable operation, low operating costs and high performance.

olmi ache 640x360

Benefits of air-cooled finned tube heat exchangers

  • Customized to your requirements
  • Very low energy consumption
  • Robust heat exchangers, built for tough duties
  • High performance
  • Low maintenance requirements

Discover our range of tailored air-cooling solutions

.

Talk to an expert

We will be happy to discuss the benefits an Alfa Laval finned tube air heat exchanger can bring you and show you how we can help improve your operation.

contact expert

Service and spare parts

Are you looking for replacement parts or field service? We can help you! Talk to one of our field service engineers.

Bolts 640x360

OEM spares available 24/7 in our ACE Webshop

Genuine spare parts for your ACE equipment are critical to uptime and profitability. At the Alfa Laval web shop, OEM quality spares are just a few clicks away. It’s easy to find the right part. Simply search using the serial number of your Alfa Laval ACE or, for any other brand of air-cooled heat exchanger, using the part specifications.

ACE-webshop-new-vignette
.

Air-cooled finned tube heat exchangers models

Alfa Laval ACE Model A

Alfa Laval air-cooled exchanger Model A

  • Vertical, sloped section(s) and fan with vertical air ejection
  • Sloped sections provide an optimized centre of gravity for safer loading and transport
  • Available with low-weight aluminium fan guard for increased maintenance safety

Download ACE model A product leaflet

Alfa Laval ACE Model C

Alfa Laval air-cooled exchanger Model C

  • Vertical air-cooler section(s) and fan with horizontal air ejection
  • Economical and compact alternative to vertical air ejection models
  • Easy access to the cooler section during service

Download ACE model C product leaflet

Alfa Laval ACE Model E

Alfa Laval air-cooled exchanger Model E

  • Horizontal air-cooler section(s) and fan(s) with vertical air ejection
  • Available in single fan to four fan configurations
  • Available with low-weight aluminium fan guard(s) for increased maintenance safety
  • VFD capable electrical drive for precise air control and power consumption

Download ACE model E product leaflet

Alfa Laval ACE Model J

Alfa Laval air-cooled exchanger Model J

  • Vertical air-cooler section(s) and fan with vertical air ejection
  • Easy access to the cooler section during service
  • Directional plenum allows efficient airflow transition from horizontal to vertical

Download ACE model J product leaflet

Alfa Laval ACE Model T

Alfa Laval air-cooled exchanger Model T

  • Horizontal air-cooler section(s) and vertical fan(s) with vertical air ejection
  • Available in configurations with one to five fans
  • Available with low-weight aluminium fan guard(s) for increased maintenance safety
  • Relatively narrow width for easy transport

Download ACE model T product leaflet

Alfa Laval ACE Model V

Alfa Laval ACE Model V

  • Sloped sections with horizontal fans and vertical air ejection
  • Modular, induced draft fan cells allow for section lengths up to 18 m (60 ft)
  • The special design reduces transportation and plot space costs as compared to horizontal section designs
  • Standard VFD fans prewired to control system, installed on unit, reduce operating costs

Download ACE model V product leaflet

Alfa Laval Olmi Model G

Alfa Laval Olmi air heat exchanger Model G

  • Modular design, ensuring rapid ordering and delivery
  • Flexible configurations
  • Designed for easy transport on a normal truck or in a 40-ft container
  • Quick and easy to install

Download ACE model G product leaflet

Alfa Laval ACE/Olmi API 661 Air Cooler

Alfa Laval Olmi air heat exchanger API 661

  • Engineered-to-order units for the toughest applications
  • Handles temperatures up to 400°C (700°F) and pressures up to 700 bar (10,000 psi)
  • Available in many materials including titanium
  • Completely pre-assembled, modularized units

Download ACE/Olmi API 661 product leaflet

Case story: Upgrade brought lower operating costs and reduced noise levels

Substantial savings in power consumption as well as reduced noise and vibration levels were the results when the fans, motors and transmissions of a 60-cell system of air-cooled finned tube heat exchangers in a European fertilizer plant were upgraded. Alfa Laval Olmi´s service organization handled the entire upgrade from initial planning to installation.

Fan blades on an air-cooled heat exchanger

Sustainable efficiency

Increase reliability and profitability with Alfa Laval air-cooled heat exchangers. Check out our brochure to find out how we can help you improve the sustainability of your plant.

Air brochure 630x360

How it works

.

Working principle ACE Model E, Olmi API 661 and Olmi Model G

Working principle ACE Model A

The hot medium (e.g. hot water or lube oil) flows through the air-cooled finned tube heat exchanger within the large number of externally finned tubes. One or more fans force air across the tubes and the heat from the hot medium is transferred to the air. To maximize heat transfer, the tubes are equipped with fins that increase the area in contact with the air.

Alfa Laval offers a great variety of air-cooled finned tube heat exchanger designs in terms of:

  • Number of fans
  • Orientation of the fans (horizontal or vertical)
  • Orientation of the tube sections (horizontal, vertical or sloped)
  • Induced or forced draft
  • Configurable plot sizes

Forced draft design

In air-cooled finned tube heat exchangers with a forced draft configuration the air passes the fan before it passes the finned tubes and the air is pushed through the tube bundles. The advantages with this include:

  • The fan and belt is not exposed to the hot exhaust air, which increases component lifetimes.
  • No temperature limit on the existing air.
  • When the tube sections are horizontal, the fan is placed under the tubes, making access during service easier and costs for structure lower.
  • Energy consumption is often lower as compared to induced draft units.

 

Induced draft design

In an air-cooled finned tube heat exchanger operating with induced draft the fan is placed after the tube sections, meaning air is pulled through the tube bundles. The advantages with this design are:

  • A more even distribution of the air flow through the tube bundles.
  • The risk of recirculating hot exhaust air is much lower thanks to a higher exit air velocity than in a forced-draft heat exchanger.

The combinations of forced/induced draft and the orientation of the fans and tube sections all have their individual advantages and ideal uses. Please contact your Alfa Laval representative for a discussion about the optimum solution for your specific conditions and application.

 

ACE - Working principle

Alfa Laval ACE how it works

Olmi - Working principle

Alfa Laval Olmi air-cooler

.

Unique air-cooled finned tube heat exchanger features

Alfa Laval finned tube air heat exchangers with HyperFin

 

 

 

 

HyperFin

Slitted fin design maximizes heat transfer.

Alfa Laval finned tube air heat exchangers with SealTight

 

 

 


SealTight

Effectively prevents leaks from the plugs in the header box.

ALOnsite

 

 

 

 

ALOnsite™

True onsite service by skilled engineers, anywhere in the world.

Discover our range of tailored air-cooling solutions

Air flow is nature’s own method of regulating temperature. Alfa Laval offers a wide range of energy-efficient high-performance systems for air-cooled heat exchange in industrial applications.

Air vignette 640x360